\nBelow is some information about our wetted probes<\/strong>. They were specifically developed to measure free surface flow<\/strong> (open channel, river or partially filled pipe).<\/p>\n<\/div>\nSM 1654<\/div>
<\/p>\n
\n\n\n\u00a0<\/td>\n<\/tr>\n |
\nApplication<\/td>\n | Open channel<\/td>\n<\/tr>\n |
\nDistance between probes<\/td>\n | From 1 up to 4 m<\/td>\n<\/tr>\n |
\nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n |
\nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n |
\nFrequency<\/td>\n | \u00a01 MHz<\/td>\n<\/tr>\n |
\nIngress protection<\/td>\n | \u00a0Type IP 68<\/td>\n<\/tr>\n |
\nATEX version<\/td>\n | \u00a0–<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n<\/div><\/div><\/div>\n SM 1686<\/div> <\/p>\n \n\n\n\u00a0<\/td>\n<\/tr>\n | \nApplication<\/td>\n | Open channel<\/td>\n<\/tr>\n | \nDistance between probes<\/td>\n | From 2 up to 15 m<\/td>\n<\/tr>\n | \nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n | \nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n | \nFrequency<\/td>\n | 500 KHz<\/td>\n<\/tr>\n | \nIngress protection<\/td>\n | Type IP 68<\/td>\n<\/tr>\n | \nATEX version<\/td>\n | –<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n<\/div><\/div><\/div>\n SM 1527<\/div> <\/p>\n \n\n\n\u00a0<\/td>\n<\/tr>\n | \nApplication<\/td>\n | Open channel<\/td>\n<\/tr>\n | \nDistance between probes<\/td>\n | From 3 up to 15 m<\/td>\n<\/tr>\n | \nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n | \nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n | \nFrequency<\/td>\n | 500 KHz<\/td>\n<\/tr>\n | \nIngress protection<\/td>\n | Type IP 68<\/td>\n<\/tr>\n | \nATEX version<\/td>\n | Disponible<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n<\/div><\/div><\/div>\n SM 1613<\/div> <\/p>\n \n\n\n\u00a0<\/td>\n<\/tr>\n | \nApplication<\/td>\n | Open channel<\/td>\n<\/tr>\n | \nDistance between probes<\/td>\n | From 3 up to 15 m<\/td>\n<\/tr>\n | \nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n | \nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n | \nFrequency<\/td>\n | 500 KHz<\/td>\n<\/tr>\n | \nIngress protection<\/td>\n | Type IP 68<\/td>\n<\/tr>\n | \nATEX version<\/td>\n | –<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n<\/div><\/div><\/div>\n SM 1690<\/div> <\/p>\n \n\n\n\u00a0<\/td>\n<\/tr>\n | \nApplication<\/td>\n | Open channel<\/td>\n<\/tr>\n | \nDistance between probes<\/td>\n | From 3 up to 15 m<\/td>\n<\/tr>\n | \nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n | \nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n | \nFrequency<\/td>\n | 500 KHz<\/td>\n<\/tr>\n | \nIngress protection<\/td>\n | Type IP 68<\/td>\n<\/tr>\n | \nATEX version<\/td>\n | –<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n<\/div><\/div><\/div>\n SM 1689<\/div> <\/p>\n \n\n\n\u00a0<\/td>\n<\/tr>\n | \nApplication<\/td>\n | River<\/td>\n<\/tr>\n | \nDistance between probes<\/td>\n | From 10 up to 30 m<\/td>\n<\/tr>\n | \nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n | \nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n | \nFrequency<\/td>\n | 200 KHz<\/td>\n<\/tr>\n | \nIngress protection<\/td>\n | Type IP 68<\/td>\n<\/tr>\n | \nATEX version<\/td>\n | –<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n<\/div><\/div><\/div>\n SM 1681<\/div> <\/p>\n \n\n\n<\/td>\n<\/tr>\n | \nApplication<\/td>\n | River<\/td>\n<\/tr>\n | \nDistance between probes<\/td>\n | From 40 up to 80 m<\/td>\n<\/tr>\n | \nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n | \nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n | \nFrequency<\/td>\n | 200 KHz<\/td>\n<\/tr>\n | \nIngress protection<\/td>\n | Type IP 68<\/td>\n<\/tr>\n | \nATEX version<\/td>\n | –<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n<\/div><\/div><\/div>\n SM 1666<\/div> \n\n\n\u00a0<\/td>\n<\/tr>\n | \nApplication<\/td>\n | River<\/td>\n<\/tr>\n | \nDistance between probes<\/td>\n | From 70 up to 250 m<\/td>\n<\/tr>\n | \nMaximum temperature allowed<\/td>\n | 60\u00b0C<\/td>\n<\/tr>\n | \nConnectic<\/td>\n | Gland connector<\/td>\n<\/tr>\n | \nFrequency<\/td>\n | 200 KHz<\/td>\n<\/tr>\n | \nIngress protection<\/td>\n | Type IP 68<\/td>\n<\/tr>\n | \nATEX version<\/td>\n | –<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n<\/div><\/div><\/div><\/h4>\n\nThis selection of models will give you an idea of our range. Please do not hesitate to contact us for more information on all of the available products.<\/em><\/p>\n<\/div><\/h4>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":5538,"menu_order":10,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"acf":[],"yoast_head":"\nWetted probes | Ultraflux - Expert in flow meters since 1974<\/title>\n\n\n\n\n\n\n\n\n\n\n\n\n\t\n
| | | | | | | |