Full pipe flow rate measurement

A full pipe (or pressure conduit) is a circular pipe entirely filled with liquid or gas fluid.

Choice of probe

The probes used for taking the measurements can be external (clamp-on) or intrusive.
Clamp-on probes are designed for temporary measurements but can also be used for permanent measurements because they are safe and easy to install.
Intrusive probes can be divided into two categories: fixed probes, which are installed where there is an absence of pressure, and probes that can be removed under pressure.

–> These categories of probes can be used to take mono-chord or multi-chord measurements.

Mono-chord system

A measuring point in the mono-chord system is made up of:

  • 1 converter
  • 1 chord = 2 probes (marked as A and B on the diagram)
 Mesure monocorde avec sondes à insertion Measurement principle with insertion probes

A and B probes are both transmitters and receivers. They alternately transmit to one other. The acoustic signal that spreads through the fluid is collected by the opposite probe.
The Upstream/Downstream and Downstream/Upstream propagation times are precisely measured (typically 0.2 ns).
The average speed along the acoustic path can be calculated using these times and the geometric position of the probes.

Multi-chord system

Mono-chord measurements can be used in the assumption that the velocity profile at the measuring point is symmetrical relative to the axis of the pipe. Using multi-chord measurements makes it easier to integrate speed profile irregularities. As such, multi-chord measurements can be used on straight lengths that are shorter than those required for mono-chord measurements.

Sondes à insertion sur conduite Sondes à insertion & conduite

Calculation method

Calculation method

Flow measurement with clamp-on probes Flow measurement with external probes

With:

TAB: propagation time of the ultrasonic wave from probe A to probe B
C: speed of sound
VUS: velocity or average speed on the ultrasonic path
Kh: hydraulic coefficient
Q: flow
D: Axial distance or Daxe (projected acoustic path along the pipe axis)
S: Section

Discover our products for full pipes:
Flow meters for liquids & flow meters for gas.